* a message begins with an asterisk ('''*''') and is terminated with a double hash ('''##''').  
 
* a message begins with an asterisk ('''*''') and is terminated with a double hash ('''##''').  
 
* a message contains fields separated by an asterisk ('''*''').  
 
* a message contains fields separated by an asterisk ('''*''').  
* a field can contain attributes (dimensions) and values separated by a hash ('''#''')
+
* a field can contain attributes (dimensions) and values separated by an asterisk ('''*''') and/or a hash ('''#''')
  
 
Example: <code>'''*field1*field2#attr1#value1*field3...fieldN##'''</code>
 
Example: <code>'''*field1*field2#attr1#value1*field3...fieldN##'''</code>

Revision as of 21:35, 20 November 2014

The OpenWebNet protocol was defined in 2000 by Bticino/Legrand to specify the communication with a Bticino home automation gateway, connected via LAN, RS-232 (serial) or USB. Here you'll get a brief overview of the OWN language syntax. To watch live the OWN messages of your Bticino gateway, you should try the Python Monitor in our Code Snippets section.



Basic Syntax Rules

A Bticino gateway sends and receives messages.

  • a message begins with an asterisk (*) and is terminated with a double hash (##).
  • a message contains fields separated by an asterisk (*).
  • a field can contain attributes (dimensions) and values separated by an asterisk (*) and/or a hash (#)

Example: *field1*field2#attr1#value1*field3...fieldN##

The OWN message syntax

Message Type Message Note
ACK *#*1## Message accepted/understood
NACK *#*0## Message not accepted/understood
Standard *WHO*WHAT*WHERE## Standard message
Status Request *#WHO*WHERE## Request a state (e.g. if a light is ON or OFF)
Attribute Request *#WHO*WHERE*ATTRIBUTE## Request attribute value
Attribute Write *#WHO*WHERE*#ATTRIBUTE*VAL1*VAL2*...*VALn## Write attribute value(s)

We know already that a standard message consists of *WHO*WHAT*WHERE##.

  • WHO identifies the service, such as scenario, light or automation. See WHO table below.
  • WHAT is the action to be performed, such as light ON/OFF or dimmer, shutter up/down etc.
  • WHERE identifies the object, which can be an area, group, an environment, or just a single light or shutter etc. Check out the WHERE table below.
  • ## remarks the end of a message. Larger facilities might have extension interfaces. Adresses connected to on one of these extension interfaces have the prefix "#4#nn, where nn stands for the 2-digit value of the extension interface number. So a message with an address on interface 7 will end with a "#4#07##.

Some Examples

*1*0*25##           Turn off light 2.5 on local interface 
 | | |
 | | +- light address 25
 | +- 0=OFF
 +- WHO=1 lighting

*0*13*19#4#06##     Launch scenario 13 of scenario list 19 on interface 6
 | |  | |
 | |  | +- #4#06 = interface 6
 | |  +- 19 = address of scenario list
 | +- scenario #13 
 +- WHO=0 scenarios

*1*1*47#4#01##      Turn on light 4.7 on interface 1 (#4#01)
*1*1*0415##         Turn on light 4.15 on local interface
*1*0*0##            Turn off all lights on local interface
*2*1*91#4#03##      open (1) shutter 9.1 in on interface 3 (#4#03)
*#4*#1*#14*0225*3## Set heating zone 1 manually ON to 22.5°C

WHERE Table

The WHERE field identifies the object, which can be an area, group, an environment, or just a single light or shutter etc.

WHERE Address
0 General (covers 11..99)
1..9 Zone/room 1 to 9
11..99 Light point 1.1 to 9.9
0110..0915
 
Light point 1.10 to 9.15
extended addresses
#1..#9 Group 1 to 9
  • A WHERE field can also come with optional parameters, separated by a hash (#), e.g. *WHERE#PAR1#PAR2#...#PARn.

WHO Table

The WHO value describes the service. Find out more about each service by clicking on the service nam in right column:

WHO Service
0 Scenarios
1 Lighting
2 Automation
3 Load Control
4 Heating
5 Burglar Alarm
6 Door Entry System
7 Multimedia
9 Auxiliary
13 Device Communication
14 Light+shutters actuators lock
15 WHO=15 - CEN
16 Sound System
17 Scenario Programming
18 Energy Management
24 Lighting Management
25 WHO=25 - CEN plus
1000 Diagnostic
1001 Automation Diagnostic
1004 Heating Diagnostic
1008 Door Entry System Diagnostic
1013 Device Diagnostic