+ | Heating is a very nice service - especially in winter. | ||
+ | |||
+ | |||
+ | ==== Some Commands Examples ==== | ||
+ | '''<pre> | ||
+ | |||
+ | Set mode | ||
+ | *4*102*5## set zone 5 in anti-freeze mode | ||
+ | *4*110*5## set zone 5 in manual mode | ||
+ | *4*303*5## set zone 5 OFF | ||
+ | |||
+ | Set temperature | ||
+ | *#4*#5*#14*0250*3## set zone 5 to 22.5°C | ||
+ | |||
+ | </pre>''' | ||
+ | |||
+ | ==== Some Request Examples ==== | ||
+ | '''<pre> | ||
+ | |||
+ | *#4*2*0## get current temp of zone 2 | ||
+ | returns *#4*2*0*0225## = temperature in zone 2 is 22.5°C | ||
+ | |||
+ | |||
+ | </pre>''' | ||
+ | |||
+ | ==== Some Monitor Message Examples ==== | ||
+ | '''<pre> | ||
+ | |||
+ | In these examples, the zone is always zone 5 | ||
+ | *#4*5*0*0161## current temperature: 16.1 °C | ||
+ | *#4*5*12*0070*3## real set point (set point + offset): 7.0 °C | ||
+ | *4*102*5## is in anti-freeze mode | ||
+ | *#4*5*14*0215*3## set point: 21.5 °C | ||
+ | |||
+ | Manual offset of zone 5 | ||
+ | *#4*5*13*00## manual offset: 0 | ||
+ | *#4*5*13*01## manual offset: +1°C | ||
+ | *#4*5*13*02## manual offset: +2°C | ||
+ | *#4*5*13*03## manual offset: +3°C | ||
+ | *#4*5*13*11## manual offset: -1°C | ||
+ | *#4*5*13*12## manual offset: -2°C | ||
+ | *#4*5*13*13## manual offset: -3°C | ||
+ | |||
+ | *4*102*#5## is in anti-freeze mode | ||
+ | |||
+ | |||
+ | |||
+ | </pre>''' | ||
+ | |||
== WHAT Table == | == WHAT Table == | ||
− | {| class="wikitable | + | {| class="wikitable" |
! style="text-align:left;"| WHAT | ! style="text-align:left;"| WHAT | ||
! style="text-align:left;"| Description | ! style="text-align:left;"| Description | ||
Line 116: | Line 165: | ||
|} | |} | ||
− | == | + | == DIMENSION Table == |
{| class="wikitable" style="float:left;" | {| class="wikitable" style="float:left;" | ||
− | ! style="text-align:left;"| | + | ! style="text-align:left;"| DIMENSION |
! style="text-align:left;"| Description | ! style="text-align:left;"| Description | ||
+ | ! style="text-align:left;"| ReadOnly/ReadWrite | ||
|- | |- | ||
|0 | |0 | ||
− | | | + | |Measures Temperature |
+ | |R | ||
+ | |- | ||
+ | |11 | ||
+ | |Fan coil Speed | ||
+ | |R | ||
+ | |- | ||
+ | |12 | ||
+ | |Complete probe status | ||
+ | |R | ||
+ | |- | ||
+ | |13 | ||
+ | |Local set offset | ||
+ | |R | ||
|- | |- | ||
− | | | + | |14 |
− | | | + | |Set Point temperature |
+ | |R/W | ||
|- | |- | ||
− | | | + | |19 |
− | | | + | |Valves status |
+ | |R | ||
|- | |- | ||
− | | | + | |20 |
− | | | + | |Actuator Status |
+ | |R | ||
|- | |- | ||
− | | | + | |22 |
− | | | + | |Split Control |
+ | |R/W | ||
|- | |- | ||
− | | | + | |30 |
− | | | + | |End date Holiday Scenario |
+ | |R/W | ||
|} | |} | ||
Latest revision as of 17:53, 8 November 2015
Heating is a very nice service - especially in winter.
Contents
Some Commands Examples
Set mode *4*102*5## set zone 5 in anti-freeze mode *4*110*5## set zone 5 in manual mode *4*303*5## set zone 5 OFF Set temperature *#4*#5*#14*0250*3## set zone 5 to 22.5°C
Some Request Examples
*#4*2*0## get current temp of zone 2 returns *#4*2*0*0225## = temperature in zone 2 is 22.5°C
Some Monitor Message Examples
In these examples, the zone is always zone 5 *#4*5*0*0161## current temperature: 16.1 °C *#4*5*12*0070*3## real set point (set point + offset): 7.0 °C *4*102*5## is in anti-freeze mode *#4*5*14*0215*3## set point: 21.5 °C Manual offset of zone 5 *#4*5*13*00## manual offset: 0 *#4*5*13*01## manual offset: +1°C *#4*5*13*02## manual offset: +2°C *#4*5*13*03## manual offset: +3°C *#4*5*13*11## manual offset: -1°C *#4*5*13*12## manual offset: -2°C *#4*5*13*13## manual offset: -3°C *4*102*#5## is in anti-freeze mode
WHAT Table
WHAT | Description |
---|---|
0 | Conditioning Mode |
1 | Heating Mode |
102 | Anti Freeze |
202 | Thermal Protection |
302 | Protection (generic) |
103 | OFF – Heating Mode |
203 | OFF – Conditioning Mode |
303 | OFF (Generic) |
110 | Manual-adjustment Mode – Heating |
210 | Manual-adjustment Mode – Conditioning |
310 | Manual-adjustment Mode (Generic) |
111 | Programming Mode – Heating |
211 | Programming Mode - Conditioning |
311 | Programming Mode (generic) |
115 | Holiday daily plan – Heating Mode |
215 | Holiday daily plan – Conditioning Mode |
315 | Holiday daily plan |
13xxx | Vacation scenario for xxx days – Heating mode (Xxx=0…999) |
23xxx | Vacation scenario for xxx days – Conditioning mode (xxx=0….999) |
33xxx | Vacation scenario for xxx days (xxx=0….999) |
3000 | Vacation scenario disabled |
11xx | Heating program x (x=1…3) |
21xx | Conditioning program x (x=1…3) |
31xx | Last activated program |
3100 | Scenario xx (xx=1…16) |
12xx | Scenario xx (xx=1...16) |
22xx | Last activated scenario |
32xx | Holiday scenario for xxx days – Heating mode (Xxx=0…999) |
3200 | Holiday scenario for xxx days – Conditioning mode (xxx=0….999) |
20 | Remote control disabled |
21 | Remote control enabled |
22 | At least one probe OFF |
23 | At least one probe in Anti Freeze |
24 | At least one probe in Manual |
30 | Failure discovered |
31 | Central Unit battery KO |
40 | Release of sensor local adjustment |
DIMENSION Table
DIMENSION | Description | ReadOnly/ReadWrite |
---|---|---|
0 | Measures Temperature | R |
11 | Fan coil Speed | R |
12 | Complete probe status | R |
13 | Local set offset | R |
14 | Set Point temperature | R/W |
19 | Valves status | R |
20 | Actuator Status | R |
22 | Split Control | R/W |
30 | End date Holiday Scenario | R/W |
WHO=3 - Load Control | WHO Table | WHO=5 - Burglar Alarm |