'''<pre>
 
'''<pre>
  
*4*102*2##     set zone 2 in anti-freeze mode
+
Set mode
*4*110*3##     set zone 3 in manual mode
+
*4*102*5##           set zone 5 in anti-freeze mode
*4*303*5##     set zone 5 OFF  
+
*4*110*5##           set zone 5 in manual mode
 +
*4*303*5##           set zone 5 OFF  
 +
 
 +
Set temperature
 +
*#4*#5*#14*0250*3##  set zone 5 to 22.5°C
  
 
</pre>'''
 
</pre>'''
Line 23: Line 27:
 
'''<pre>
 
'''<pre>
  
In these examples, 65 is the zone
+
In these examples, the zone is always zone 5
 
*#4*5*0*0161##      current temperature: 16.1 °C  
 
*#4*5*0*0161##      current temperature: 16.1 °C  
 
*#4*5*12*0070*3##    real set point (set point + offset): 7.0 °C  
 
*#4*5*12*0070*3##    real set point (set point + offset): 7.0 °C  
 
*4*102*5##          is in anti-freeze mode  
 
*4*102*5##          is in anti-freeze mode  
 
*#4*5*14*0215*3##    set point: 21.5 °C  
 
*#4*5*14*0215*3##    set point: 21.5 °C  
 +
 +
Manual offset of zone 5
 
*#4*5*13*00##        manual offset: 0  
 
*#4*5*13*00##        manual offset: 0  
 +
*#4*5*13*01##        manual offset: +1°C
 +
*#4*5*13*02##        manual offset: +2°C
 +
*#4*5*13*03##        manual offset: +3°C
 +
*#4*5*13*11##        manual offset: -1°C
 +
*#4*5*13*12##        manual offset: -2°C
 +
*#4*5*13*13##        manual offset: -3°C
 +
 
*4*102*#5##          is in anti-freeze mode  
 
*4*102*#5##          is in anti-freeze mode  
  

Latest revision as of 17:53, 8 November 2015

Heating is a very nice service - especially in winter.


Some Commands Examples


Set mode
*4*102*5##           set zone 5 in anti-freeze mode
*4*110*5##           set zone 5 in manual mode
*4*303*5##           set zone 5 OFF 

Set temperature
*#4*#5*#14*0250*3##  set zone 5 to 22.5°C

Some Request Examples


*#4*2*0##       get current temp of zone 2
                returns *#4*2*0*0225## = temperature in zone 2 is 22.5°C


Some Monitor Message Examples


In these examples, the zone is always zone 5
*#4*5*0*0161##       current temperature: 16.1 °C 
*#4*5*12*0070*3##    real set point (set point + offset): 7.0 °C 
*4*102*5##           is in anti-freeze mode 
*#4*5*14*0215*3##    set point: 21.5 °C 

Manual offset of zone 5
*#4*5*13*00##        manual offset: 0 
*#4*5*13*01##        manual offset: +1°C
*#4*5*13*02##        manual offset: +2°C
*#4*5*13*03##        manual offset: +3°C
*#4*5*13*11##        manual offset: -1°C
*#4*5*13*12##        manual offset: -2°C
*#4*5*13*13##        manual offset: -3°C

*4*102*#5##          is in anti-freeze mode 



WHAT Table

WHAT Description
0 Conditioning Mode
1 Heating Mode
102 Anti Freeze
202 Thermal Protection
302 Protection (generic)
103 OFF – Heating Mode
203 OFF – Conditioning Mode
303 OFF (Generic)
110 Manual-adjustment Mode – Heating
210 Manual-adjustment Mode – Conditioning
310 Manual-adjustment Mode (Generic)
111 Programming Mode – Heating
211 Programming Mode - Conditioning
311 Programming Mode (generic)
115 Holiday daily plan – Heating Mode
215 Holiday daily plan – Conditioning Mode
315 Holiday daily plan
13xxx Vacation scenario for xxx days – Heating mode (Xxx=0…999)
23xxx Vacation scenario for xxx days – Conditioning mode (xxx=0….999)
33xxx Vacation scenario for xxx days (xxx=0….999)
3000 Vacation scenario disabled
11xx Heating program x (x=1…3)
21xx Conditioning program x (x=1…3)
31xx Last activated program
3100 Scenario xx (xx=1…16)
12xx Scenario xx (xx=1...16)
22xx Last activated scenario
32xx Holiday scenario for xxx days – Heating mode (Xxx=0…999)
3200 Holiday scenario for xxx days – Conditioning mode (xxx=0….999)
20 Remote control disabled
21 Remote control enabled
22 At least one probe OFF
23 At least one probe in Anti Freeze
24 At least one probe in Manual
30 Failure discovered
31 Central Unit battery KO
40 Release of sensor local adjustment

DIMENSION Table

DIMENSION Description ReadOnly/ReadWrite
0 Measures Temperature R
11 Fan coil Speed R
12 Complete probe status R
13 Local set offset R
14 Set Point temperature R/W
19 Valves status R
20 Actuator Status R
22 Split Control R/W
30 End date Holiday Scenario R/W