Difference between revisions of "WHO=4 - Heating"
Jump to navigation
Jump to search
(3 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
'''<pre> | '''<pre> | ||
− | *4*102* | + | Set mode |
− | *4*110* | + | *4*102*5## set zone 5 in anti-freeze mode |
− | *4*303*5## | + | *4*110*5## set zone 5 in manual mode |
+ | *4*303*5## set zone 5 OFF | ||
+ | |||
+ | Set temperature | ||
+ | *#4*#5*#14*0250*3## set zone 5 to 22.5°C | ||
</pre>''' | </pre>''' | ||
Line 29: | Line 33: | ||
*#4*5*14*0215*3## set point: 21.5 °C | *#4*5*14*0215*3## set point: 21.5 °C | ||
− | + | Manual offset of zone 5 | |
*#4*5*13*00## manual offset: 0 | *#4*5*13*00## manual offset: 0 | ||
*#4*5*13*01## manual offset: +1°C | *#4*5*13*01## manual offset: +1°C |
Latest revision as of 17:53, 8 November 2015
Heating is a very nice service - especially in winter.
Contents
Some Commands Examples
Set mode *4*102*5## set zone 5 in anti-freeze mode *4*110*5## set zone 5 in manual mode *4*303*5## set zone 5 OFF Set temperature *#4*#5*#14*0250*3## set zone 5 to 22.5°C
Some Request Examples
*#4*2*0## get current temp of zone 2 returns *#4*2*0*0225## = temperature in zone 2 is 22.5°C
Some Monitor Message Examples
In these examples, the zone is always zone 5 *#4*5*0*0161## current temperature: 16.1 °C *#4*5*12*0070*3## real set point (set point + offset): 7.0 °C *4*102*5## is in anti-freeze mode *#4*5*14*0215*3## set point: 21.5 °C Manual offset of zone 5 *#4*5*13*00## manual offset: 0 *#4*5*13*01## manual offset: +1°C *#4*5*13*02## manual offset: +2°C *#4*5*13*03## manual offset: +3°C *#4*5*13*11## manual offset: -1°C *#4*5*13*12## manual offset: -2°C *#4*5*13*13## manual offset: -3°C *4*102*#5## is in anti-freeze mode
WHAT Table
WHAT | Description |
---|---|
0 | Conditioning Mode |
1 | Heating Mode |
102 | Anti Freeze |
202 | Thermal Protection |
302 | Protection (generic) |
103 | OFF – Heating Mode |
203 | OFF – Conditioning Mode |
303 | OFF (Generic) |
110 | Manual-adjustment Mode – Heating |
210 | Manual-adjustment Mode – Conditioning |
310 | Manual-adjustment Mode (Generic) |
111 | Programming Mode – Heating |
211 | Programming Mode - Conditioning |
311 | Programming Mode (generic) |
115 | Holiday daily plan – Heating Mode |
215 | Holiday daily plan – Conditioning Mode |
315 | Holiday daily plan |
13xxx | Vacation scenario for xxx days – Heating mode (Xxx=0…999) |
23xxx | Vacation scenario for xxx days – Conditioning mode (xxx=0….999) |
33xxx | Vacation scenario for xxx days (xxx=0….999) |
3000 | Vacation scenario disabled |
11xx | Heating program x (x=1…3) |
21xx | Conditioning program x (x=1…3) |
31xx | Last activated program |
3100 | Scenario xx (xx=1…16) |
12xx | Scenario xx (xx=1...16) |
22xx | Last activated scenario |
32xx | Holiday scenario for xxx days – Heating mode (Xxx=0…999) |
3200 | Holiday scenario for xxx days – Conditioning mode (xxx=0….999) |
20 | Remote control disabled |
21 | Remote control enabled |
22 | At least one probe OFF |
23 | At least one probe in Anti Freeze |
24 | At least one probe in Manual |
30 | Failure discovered |
31 | Central Unit battery KO |
40 | Release of sensor local adjustment |
DIMENSION Table
DIMENSION | Description | ReadOnly/ReadWrite |
---|---|---|
0 | Measures Temperature | R |
11 | Fan coil Speed | R |
12 | Complete probe status | R |
13 | Local set offset | R |
14 | Set Point temperature | R/W |
19 | Valves status | R |
20 | Actuator Status | R |
22 | Split Control | R/W |
30 | End date Holiday Scenario | R/W |