Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Standard Command *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
Standard Request *#WHO*WHERE##
Examples:
*#2*15## Returns the current status of shutter 15
WHAT Table
WHAT | Description |
---|---|
0 | STOP |
1 | UP |
2 | DOWN |
WHO=1 - Lighting | WHO Table | WHO=3 - Power Management |