Difference between revisions of "WHO=2 - Automation"
Jump to navigation
Jump to search
(Created page with "Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP, Unfortunatelly a status request is not possible, so you never know if your shutters a...") |
|||
Line 1: | Line 1: | ||
− | Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP | + | Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed. |
==== Standard Message <tt>*WHO*WHAT*WHERE##</tt>==== | ==== Standard Message <tt>*WHO*WHAT*WHERE##</tt>==== |
Revision as of 16:17, 21 November 2014
Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Standard Message *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
WHAT Table
Value | Description |
---|---|
0 | STOP |
1 | UP |
2 | DOWN |
WHERE | Address |
---|---|
0 | General |
1..9 | Environment 1 to 9 |
11..99 | Light point 1.1 to 9.9 |
0110..0915 | Light point 1.10 to 9.15 |
#1..#9 | Group 1 to 9 |
[[WHO=1 - Lighting] | WHO Table | WHO=3 - Load Control |