Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP, Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
+
Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
  
 
==== Standard Message <tt>*WHO*WHAT*WHERE##</tt>====
 
==== Standard Message <tt>*WHO*WHAT*WHERE##</tt>====

Revision as of 16:17, 21 November 2014

Automation is quite simple, since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.

Standard Message *WHO*WHAT*WHERE##

Examples:

*2*1*15##        Shutter 15 UP
*2*2*15##        Shutter 15 DOWN
*2*0*15##        Shutter 15 STOP

WHAT Table

Value Description
0 STOP
1 UP
2 DOWN
WHERE Address
0 General
1..9 Environment 1 to 9
11..99 Light point 1.1 to 9.9
0110..0915 Light point 1.10 to 9.15
#1..#9 Group 1 to 9