Difference between revisions of "WHO=2 - Automation"
Jump to navigation
Jump to search
| Line 11: | Line 11: | ||
== WHAT Table== | == WHAT Table== | ||
{| class="wikitable" style="float:left;" | {| class="wikitable" style="float:left;" | ||
| − | ! style="text-align:left;"| | + | ! style="text-align:left;"| WHAT |
! style="text-align:left;"| Description | ! style="text-align:left;"| Description | ||
|- | |- | ||
Revision as of 16:38, 21 November 2014
Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Standard Message *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
WHAT Table
| WHAT | Description |
|---|---|
| 0 | STOP |
| 1 | UP |
| 2 | DOWN |
| WHERE | Address |
|---|---|
| 0 | General |
| 1..9 | Environment 1 to 9 |
| 11..99 | Light point 1.1 to 9.9 |
| 0110..0915 | Light point 1.10 to 9.15 |
| #1..#9 | Group 1 to 9 |
| WHO=1 - Lighting | WHO Table | WHO=3 - Load Control |