Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Standard Message *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
WHAT Table
WHAT | Description |
---|---|
0 | STOP |
1 | UP |
2 | DOWN |
WHERE | Address |
---|---|
0 | General |
1..9 | Environment 1 to 9 |
11..99 | Light point 1.1 to 9.9 |
0110..0915 | Light point 1.10 to 9.15 |
#1..#9 | Group 1 to 9 |
WHO=1 - Lighting | WHO Table | WHO=3 - Load Control |