Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
 
Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
  
==== Standard Message <tt>*WHO*WHAT*WHERE##</tt>====
+
==== Standard Command <tt>*WHO*WHAT*WHERE##</tt>====
 
Examples:
 
Examples:
 
<pre>
 
<pre>
Line 7: Line 7:
 
*2*2*15##        Shutter 15 DOWN
 
*2*2*15##        Shutter 15 DOWN
 
*2*0*15##        Shutter 15 STOP
 
*2*0*15##        Shutter 15 STOP
 +
</pre>
 +
 +
==== Standard REQUEST <tt>*#WHO*WHERE##</tt>====
 +
Examples:
 +
<pre>
 +
*#2*15##      Returns the current status of shutter 15
 
</pre>
 
</pre>
  

Revision as of 19:16, 2 November 2015

Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.

Standard Command *WHO*WHAT*WHERE##

Examples:

*2*1*15##        Shutter 15 UP
*2*2*15##        Shutter 15 DOWN
*2*0*15##        Shutter 15 STOP

Standard REQUEST *#WHO*WHERE##

Examples:

*#2*15##       Returns the current status of shutter 15

WHAT Table

WHAT Description
0 STOP
1 UP
2 DOWN


WHO=1 - Lighting WHO Table WHO=3 - Load Control