Difference between revisions of "WHO=3 - Power Management"
Jump to navigation
Jump to search
}
Line 31: | Line 31: | ||
|3 | |3 | ||
|Remove Forced | |Remove Forced | ||
− | | | + | |- |
} | } | ||
+ | |||
== DIMENSION Table== | == DIMENSION Table== | ||
Line 53: | Line 54: | ||
|4 | |4 | ||
|Energy | |Energy | ||
− | | | + | |- |
} | } | ||
Revision as of 19:24, 2 November 2015
Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Contents
Standard Command *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
Standard Request *#WHO*WHERE##
Examples:
*#2*15## Returns the current status of shutter 15
WHAT Table
}DIMENSION Table
WHAT | Description |
---|---|
0 | Disabled |
1 | Enabled |
2 | Forced |
3 | Remove Forced |
DIMENSION | Description |
---|---|
0 | All dimensions |
1 | Voltage |
2 | Current |
3 | Power |
4 | Energy |
WHO=2 - Automation | WHO Table | WHO=4 - Heating |