Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Contents
Standard Command *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP *2*2*15## Shutter 15 DOWN *2*0*15## Shutter 15 STOP
Standard Request *#WHO*WHERE##
Examples:
*#2*15## Returns the current status of shutter 15
WHAT Table
WHAT | Description |
---|---|
0 | Disabled |
1 | Enabled |
2 | Forced |
3 | Remove Forced |
DIMENSION Table
DIMENSION | Description |
---|---|
0 | All dimensions |
1 | Voltage |
2 | Current |
3 | Power |
4 | Energy |
WHO=2 - Automation | WHO Table | WHO=4 - Heating |