WHO=1 - Lighting
Standard Message
In the table above, we learned a Standard Message consists of *WHO*WHAT*WHERE## .
- WHO identifies the service, such as scenario, light or automation
- WHAT is the action to be performed, such as light ON/OFF or dimmer, shutter up/down etc.
- WHERE identifies the object, which can be an area, group, an environment, or just a single light or shutter etc. A WHERE field can also come with optional parameters, separated by a hash (#), e.g. *WHERE#PAR1#PAR2#...#PARn
WHAT Table
| Value | Description |
|---|---|
| 0 | OFF |
| 0#x | Turn off at x speed (*) |
| 1 | ON |
| 1#x | Turn on at x speed (*) |
| 2 | Set dimmer to 20% |
| 3 | Set dimmer to 30% |
| 4 | Set dimmer to 40% |
| 5 | Set dimmer to 50% |
| 6 | Set dimmer to 60% |
| 7 | Set dimmer to 70% |
| 8 | Set dimmer to 80% |
| 9 | Set dimmer to 90% |
| 10 | Set dimmer to 100% |
| 11 | ON for 1 min |
| 12 | ON for 2 min |
| 13 | ON for 3 min |
| 14 | ON for 4 min |
| 15 | ON for 5 min |
| 16 | ON for 15 min |
| 17 | ON for 30 sec |
| 18 | ON for 0.5 sec |
| 19 | NO LOAD (dimmer) |
| 20 | Blinking for 0.5 sec |
| 21 | Blinking for 1 sec |
| 22 | Blinking for 1.5 sec |
| 23 | Blinking for 2 sec |
| 24 | Blinking for 2.5 sec |
| 25 | Blinking for 3 sec |
| 26 | Blinking for 3.5 sec |
| 27 | Blinking for 4 sec |
| 28 | Blinking for 4.5 sec |
| 29 | Blinking for 5 sec |
| 30 | Up one level (dimmer) |
| 30#x#y | Up x levels at y speed (*) |
| 31 | Down one level (dimmer) |
| 31#x#y | Down x levels at y speed (*) |
| 1000 | (not sure yet about this) |
| (*) Speed: 0..255 (0=now, 255=slowest) |
| WHERE | Address |
|---|---|
| 0 | General (covers 11..99) |
| 1..9 | Zone/room 1 to 9 |
| 11..99 | Light point 1.1 to 9.9 |
| 0110..0915 | Light point 1.10 to 9.15 extended addresses |
| #1..#9 | Group 1 to 9 |