WHO=1 - Lighting
Standard Message
In the table above, we learned a Standard Message consists of *WHO*WHAT*WHERE##
.
- WHO identifies the service, such as scenario, light or automation
- WHAT is the action to be performed, such as light ON/OFF or dimmer, shutter up/down etc.
- WHERE identifies the object, which can be an area, group, an environment, or just a single light or shutter etc. A WHERE field can also come with optional parameters, separated by a hash (#), e.g. *WHERE#PAR1#PAR2#...#PARn
The WHAT Table
Value Description ------------------------------------ 0 OFF 1 ON 2 Set dimmer to 20% 3 Set dimmer to 30% 4 Set dimmer to 40% 5 Set dimmer to 50% 6 Set dimmer to 60% 7 Set dimmer to 70% 8 Set dimmer to 80% 9 Set dimmer to 90% 10 Set dimmer to 100% 11 ON for 1 min 12 ON for 2 min 13 ON for 3 min 14 ON for 4 min 15 ON for 5 min 16 ON for 15 min 17 ON for 30 min 18 ON for 0.5 sec 20 Blinking for 0.5 sec 21 Blinking for 1 sec 22 Blinking for 1.5 sec 23 Blinking for 2 sec 24 Blinking for 2.5 sec 25 Blinking for 3 sec 26 Blinking for 3.5 sec 27 Blinking for 4 sec 28 Blinking for 4.5 sec 29 Blinking for 5 sec 30 Dimmer up one step 31 DImmer down one step 0#x Turn off at x speed for step 1#x Turn on at x speed for step 30#x#y Up of x levels at y speed for steep 31#x#y Down of x levels at y speed for step1000 1000 It accepts a parameter that is the value of what table