Automation is quite simple since there are only 3 commands available: UP, DOWN and STOP. Unfortunatelly a status request is not possible, so you never know if your shutters are opened or closed.
Standard Command *WHO*WHAT*WHERE##
Examples:
*2*1*15## Shutter 15 UP
*2*2*15## Shutter 15 DOWN
*2*0*15## Shutter 15 STOP
Standard Request *#WHO*WHERE##
Examples:
*#2*15## Returns the current status of shutter 15
WHAT Table
}
DIMENSION Table
| WHAT
|
Description
|
| 0
|
Disabled
|
| 1
|
Enabled
|
| 2
|
Forced
|
| 3
|
Remove Forced
|
}
| DIMENSION
|
Description
|
| 0
|
All dimensions
|
| 1
|
Voltage
|
| 2
|
Current
|
| 3
|
Power
|
| 4
|
Energy
|