Heating is a very nice service - especially in winter.
Some Commands Examples
*4*102*2## set zone 2 in anti-freeze mode
*4*110*3## set zone 3 in manual mode
*4*303*5## set zone 5 OFF
Some Request Examples
*#4*2*0## get current temp of zone 2
returns *#4*2*0*0225## = temperature in zone 2 is 22.5°C
Some Monitor Message Examples
In these examples, 65 is the zone
*#4*5*0*0161## current temperature: 16.1 °C
*#4*5*12*0070*3## real set point (set point + offset): 7.0 °C
*4*102*5## is in anti-freeze mode
*#4*5*14*0215*3## set point: 21.5 °C
*#4*5*13*00## manual offset: 0
*4*102*#5## is in anti-freeze mode
WHAT Table
| WHAT
|
Description
|
| 0
|
Conditioning Mode
|
| 1
|
Heating Mode
|
| 102
|
Anti Freeze
|
| 202
|
Thermal Protection
|
| 302
|
Protection (generic)
|
| 103
|
OFF – Heating Mode
|
| 203
|
OFF – Conditioning Mode
|
| 303
|
OFF (Generic)
|
| 110
|
Manual-adjustment Mode – Heating
|
| 210
|
Manual-adjustment Mode – Conditioning
|
| 310
|
Manual-adjustment Mode (Generic)
|
| 111
|
Programming Mode – Heating
|
| 211
|
Programming Mode - Conditioning
|
| 311
|
Programming Mode (generic)
|
| 115
|
Holiday daily plan – Heating Mode
|
| 215
|
Holiday daily plan – Conditioning Mode
|
| 315
|
Holiday daily plan
|
| 13xxx
|
Vacation scenario for xxx days – Heating mode (Xxx=0…999)
|
| 23xxx
|
Vacation scenario for xxx days – Conditioning mode (xxx=0….999)
|
| 33xxx
|
Vacation scenario for xxx days (xxx=0….999)
|
| 3000
|
Vacation scenario disabled
|
| 11xx
|
Heating program x (x=1…3)
|
| 21xx
|
Conditioning program x (x=1…3)
|
| 31xx
|
Last activated program
|
| 3100
|
Scenario xx (xx=1…16)
|
| 12xx
|
Scenario xx (xx=1...16)
|
| 22xx
|
Last activated scenario
|
| 32xx
|
Holiday scenario for xxx days – Heating mode (Xxx=0…999)
|
| 3200
|
Holiday scenario for xxx days – Conditioning mode (xxx=0….999)
|
| 20
|
Remote control disabled
|
| 21
|
Remote control enabled
|
| 22
|
At least one probe OFF
|
| 23
|
At least one probe in Anti Freeze
|
| 24
|
At least one probe in Manual
|
| 30
|
Failure discovered
|
| 31
|
Central Unit battery KO
|
| 40
|
Release of sensor local adjustment
|
DIMENSION Table
| DIMENSION
|
Description
|
ReadOnly/ReadWrite
|
| 0
|
Measures Temperature
|
R
|
| 11
|
Fan coil Speed
|
R
|
| 12
|
Complete probe status
|
R
|
| 13
|
Local set offset
|
R
|
| 14
|
Set Point temperature
|
R/W
|
| 19
|
Valves status
|
R
|
| 20
|
Actuator Status
|
R
|
| 22
|
Split Control
|
R/W
|
| 30
|
End date Holiday Scenario
|
R/W
|